Non-charged equipment

The Imaging & Optics Facility provides a number of non-charged devices for sample preparation or checking, as well as experimental accessories. These resources do not require a system training, but need to be booked in PPMS nevertheless. An introduction to newcomers is required before any instrumentation can be used.

Zeiss Axio Imager

Location (I06.U1.403): book in PPMS

  • Manual stage
  • Light sources: halogen lamp +CoolLED p300 SB light
  • Detectors: monochromatic camera
  • Software: Zen 2.1
  • Objectives (M27 thread):
  1. Plan-Apochromat 10x/0.45 (420640-9900), WD=2.1 mm
  2. Plan APOCHROMAT 20x/0.8 (420650-9901), WD=0.55 mm (D=0.17 mm)
  3. empty
  4. Plan-Apochromat 40x/1.2 Water, WD=0.28 mm
  5. Plan APOCHROMAT 20x/0.5 dipping (420650-9901), WD=0.22mm
Leica M165FC stereo microscope

Location: (room i04.U1.019): book in PPMS

  • Different illumination option in light-base
  • CoolLED p100 LED
  • Filters-sets for DAPI (Ex:436/20 Em:480/40), GFP1 (Ex:425/60 Em:505/40), GFP2 (Ex:480/40 Em:510LP), RFP (Ex:546/10 Em:570LP)
  • Hamamatsu Orca Flash R2 camera (6.45 x 6.45 um pixel size)

System manual is available on SeaFile (login required).

Leica M205 FCA stereo microscope

Location: (room i24.U1.015): book in PPMS

  • Objective Planapo 1.0x M-series.0x M-se
  • Different illumination option in light-base
  • CoolLED pE300 SB LED
  • Filters-sets for DAPI (Ex:350/50 Em:460/50), GFP (Ex:470/40 Em:525/50), RFP (Ex:546/10 Em:590LP)
Olympus SZX16 Stereo - 0.5x - Camera; BFB

Location: room i04.U1.015  book in PPMS

  • Acquisition software: Cell Sense Entry
  • 0.5x objective + camera
  • Pixel size: 12.50µm/pixel (at 1x magnification)

User Guideline is available on SeaFile (login required).

Olympus SZX16 Stereo - 1x - Camera - LBE

Location: room i06.U1.403 – book in PPMS

Acquisition software: Cell Sense Entry

  • 1.0x objective + camera
  • Pixel size: 6,42 µm/pixel (at 1x magnification)

User Guideline is available on SeaFile (login required).

Zeiss Stereo Discovery
 

(room i06.U1.406)

Additional Equipment: Automated Rental System
 The Imaging & Optics Facility  has additional equipment that can be used via our Automate Rental System. The use of this equipment might require user-rights. The available rentals can be found here: